Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report

Tolga Eryılmaz, Ali Çağrı Tekin, Şafak Uygur.


Abstract
Two-staged flexor tendon repair rely on the effect of the pseudo-tendon sheath that developed by the effect of the silicone tendon prosthesis. The second stage of the reconstruction is performed 1 to 6 months after the first operation by removal of the silicone tendon prosthesis and tendon grafting. In this study, we are presenting a removal of silicone prosthesis 6 years after insertion for flexor tendon reconstruction.

Key words: Hunter prosthesis, silicone tendon prosthesis, two-staged flexor tendon reconstruction


 
ARTICLE TOOLS
Abstract
PDF Fulltext
How to cite this articleHow to cite this article
Citation Tools
Related Records
 Articles by Tolga Eryılmaz
Articles by Ali Çağrı Tekin
Articles by Şafak Uygur
on Google
on Google Scholar


How to Cite this Article
Pubmed Style

Tolga Eryılmaz, Ali Cağrı Tekin, Şafak Uygur. Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report. Hand Microsurg. 2012; 1(1): 40-42. doi:10.2399/emd.12.76486


Web Style

Tolga Eryılmaz, Ali Cağrı Tekin, Şafak Uygur. Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report. https://handmicrosurgeryjournal.com/?mno=163378 [Access: September 14, 2024]. doi:10.2399/emd.12.76486


AMA (American Medical Association) Style

Tolga Eryılmaz, Ali Cağrı Tekin, Şafak Uygur. Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report. Hand Microsurg. 2012; 1(1): 40-42. doi:10.2399/emd.12.76486



Vancouver/ICMJE Style

Tolga Eryılmaz, Ali Cağrı Tekin, Şafak Uygur. Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report. Hand Microsurg. (2012), [cited September 14, 2024]; 1(1): 40-42. doi:10.2399/emd.12.76486



Harvard Style

Tolga Eryılmaz, Ali Cağrı Tekin, Şafak Uygur (2012) Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report. Hand Microsurg, 1 (1), 40-42. doi:10.2399/emd.12.76486



Turabian Style

Tolga Eryılmaz, Ali Cağrı Tekin, Şafak Uygur. 2012. Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report. Hand and Microsurgery, 1 (1), 40-42. doi:10.2399/emd.12.76486



Chicago Style

Tolga Eryılmaz, Ali Cağrı Tekin, Şafak Uygur. "Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report." Hand and Microsurgery 1 (2012), 40-42. doi:10.2399/emd.12.76486



MLA (The Modern Language Association) Style

Tolga Eryılmaz, Ali Cağrı Tekin, Şafak Uygur. "Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report." Hand and Microsurgery 1.1 (2012), 40-42. Print. doi:10.2399/emd.12.76486



APA (American Psychological Association) Style

Tolga Eryılmaz, Ali Cağrı Tekin, Şafak Uygur (2012) Removal of a silicone tendon prosthesis six years after insertion for flexor tendon reconstruction: a case report. Hand and Microsurgery, 1 (1), 40-42. doi:10.2399/emd.12.76486





Most Viewed Articles
Most Accessed Articles

  • Giant intramuscular lipoma of arm: A case report and review of the literature
    Muzaffer Durmus, Ahmet Demirhan Dal, Abdul Kerim Yapici, Sedat Avsar, Yalcin Bayram
    Hand Microsurg. 2014; 3(3): 87-90
    » Abstract » doi: 10.5455/handmicrosurg.173820

  • Cubital tunnel syndrome due to heterotrophic ossification caused by radial head fracture: A case report
    Seyitali Gumustas, Haci Bayram Tosun, Ismail Agir, Abuzer Uludag
    Hand Microsurg. 2014; 3(1): 24-28
    » Abstract » doi: 10.5455/handmicrosurg.1577

  • Munchausen’s syndrome or pure self-mutilation? A case of self-inflicted tendon injury
    Burak Kaya, Servet Elcin Alpat, Mehmet Sonmez, Cem Cerkez, Savas Serel
    Hand Microsurg. 2014; 3(3): 83-86
    » Abstract » doi: 10.5455/handmicrosurg.172607

  • Radial nerve grafting in high energy humeral fractures
    Yusuf Gürbüz, Tahir Sadık Sügün, Kemal Özaksar, Murat Kayalar, Tulgar Toros, İbrahim Kaplan
    Hand Microsurg. 2012; 1(2): 60-64
    » Abstract » doi: 10.2399/emd.12.58077

  • The utility of onion extract gel containing topical allantoin and heparin after surgical treatment of upper extremity burn scars
    Mehmet Ihsan Okur, Alpagan Mustafa Yildirim, Bilsev Ince
    Hand Microsurg. 2014; 3(3): 74-79
    » Abstract » doi: 10.5455/handmicrosurg.172436

  • Most Downloaded
    Top Downloaded Articles

  • Bone island and hand involvement – A short review
    Ganesh Singh Dharmshaktu, Binit Singh
    Hand Microsurg. 2018; 7(2): 93-97
    » Abstract » doi: 10.5455/handmicrosurg.258665

  • Lipofibromatous hamartoma of the digital nerve: A case report
    Emin Sir, Alper Aksoy
    Hand Microsurg. 2018; 7(1): 45-48
    » Abstract » doi: 10.5455/handmicrosurg.255406

  • Love sign’s love for glomus tumor
    Ankit Shukla, Varun Verma, Roshni Shukla, Rajesh Chaudhary, Saurab Sharma, Sajid Mohammad
    Hand Microsurg. 2018; 7(2): 105-108
    » Abstract » doi: 10.5455/handmicrosurg.279749

  • Synovial chondromatosis of the wrist
    Murat Kayalar, Abuzer Uludag, Basak Doganavsargil Yakut, Ahmet Savran
    Hand Microsurg. 2018; 7(2): 109-111
    » Abstract » doi: 10.5455/handmicrosurg.269392

  • The three bony point relationship of the elbow-Why is there still a lack of consensus?
    Supreeth Nekkanti, Dama Kondaiah Naidu, Jasmine Sebastin, Kamal Prasad, Mohan Yeshwanth, Archana Meka
    Hand Microsurg. 2018; 7(2): 79-82
    » Abstract » doi: 10.5455/handmicrosurg.291476

  • Most Cited Articles
    Most Cited Articles